Table of Contents
Advanced instrumentation techniques question bank & Blueprint for B pharmacy 8 semester
Advanced instrumentation techniques question bank & Blueprint for B pharmacy 8 semesters is released by rguhs Bangalore, it contains all important questions, according to the syllabus. For Download the Questions bank click the download button given in below of this article.
Long essay 10 marks instrumentation techniques question bank
- Write the principle involved in NMR spectrometer. Add a note on factors affecting on
Shielding and de -shielding in NMR Spectra. - Explain the principle and working of TGA. (Thermal gravimetric analysis)
- Discuss in detail the validation parameter for bio analytical methods as per ICH
guidelines. - Explain the fundamental principles and instrumental arrangements of NMR. Write a
detail note on Octant rule - Discuss the principle and working of DTA. (Differential Thermal Analysis)
- Discuss background and principles of Bio analytical method validation as per USFDA
regulations - Discuss in detail various ionization techniques employed in the Mass Spectroscopy.
- Explain the principle and working of TGA. (Thermal gravimetric analysis)
- Write the principle involved in crystallographic studies by X- ray diffraction. Give the
importance of Braggs law in X-ray diffraction spectroscopy. - Explain instrumentation of Mass Spectrometer and its applications.
- Discuss background and principles of Bio analytical method validation as per USFDA
regulations - Explain the production and detection of X-rays by Debye scherrer method
- Write a note on coupling and decoupling methods and its significance in NMR
Spectroscopy. - Explain the production and detection of X-rays by Debye Scherrer method.
- Discuss concept of TQM. Add a note on ICH-EG guidelines.
- Explain the principle involved in the Electron impact of MALDI ionization
techniques. Write its merits and demerits. Explain the Quadra pole mass analyzer. - Define and derive the Braggs law and explain rotating crystal technique.
Chemical ionization. - Discuss in detail the validation parameter for bio-analytical methods as per USFDA.
guidelines. - Write a note on Coupling and Decoupling methods in NMR Spectroscopy
- Explain validation of analytical method of LC as per ICH guidelines
- Write the principle of differential scanning calorimeter. What factors are responsible?
- Write a note on Coupling and Decoupling methods in NMR Spectroscopy.
- Explain validation of analytical method of LC as per ICH guidelines
- Define validation; explain the types of process validation
- Write a note on coupling and decoupling methods and its significance in NMR
Spectroscopy. - Discuss concept of TQM. Add a note on ICH-EG guidelines
- Discuss the instrumentation and application of TGA
- Explain the principle involved in the Chemical ionization. Write the merit and
demerits. Explain the working of Quadra pole and Ion trap mass analyzer. - Discuss the principle and working of DTA. (Differential Thermal Analysis)
- Write the principle involved in the X-ray crystallography. Explain the importance of
structural elucidation in X-ray diffraction spectroscopy
Short essay 5 marks instrumentation techniques question bank
- Explain chemical shift and factors influencing on Chemical shift.
- Discuss the instrumentation and application of DSC.
- Explain the methodology involved in the qualification of fluorimeter.
- Write a note on single crystal diffraction and powder diffraction.
- Classify different kinds of ELISA and explain each of them in details.
- Explain the methodology involved in the qualification of UV-VIS Spectrophotometer.
- Enlist different X-ray diffraction techniques and explain the any one detail.
- Describe the principle and procedure involved in the solid phase extraction.
- Explain the methodology involved in the qualification of GC.
- Write fragmentation process in Mass Spectroscopy.
- Describe the theory of Mass spectrometry
- Explain the methodology involved in the qualification of HPLC.
- Write the importance of Radio immune assay.
- Limitations and application of Radio Immuno Assay.
- Explain the various derivatization techniques in GC.
- Write the various applications of X-ray diffraction methods.
- Discuss the principle and application of DSC.
- Discuss in detail about the HPTLC technique
- Describe the rules for fragmentation of molecules in MS with suitable examples.
- Discuss the instrumentation and application of DSC.
- What is Chemical Shift? Explain with examples different factors influencing Chemical
Shift. - Discuss the identification powder diffraction pattern in X-ray diffraction spectroscopy.
- Classify different kinds of ELISA and explain each of them in details.
- Explain the methodology involved in the qualification of UV-VIS Spectrophotometer.
- Explain the principle and different methods of Radio Immuno Assay.
- Describe the principle and procedure involved in the solid phase extraction.
- What is theoretical plate, HETP, retention and asymmetry factor
- Discuss the principle and working of DTA.
- Describe the theory of Mass spectrometry
- Explain the methodology involved in the qualification of HPLC.
- Write the importance of Radio immune assay.
- Explain the concept of ELISA and its application as the diagnostic test for HIV.
- Explain validation parameter for electronic balance.
- Explain the terms of Chemical shift and Spin-Spin coupling, Coupling constant.
- Explain the chromatographic techniques and its applications
- Describe the principle and procedure involved in the solid phase extraction
- Explain Spin-Spin coupling and coupling constant.
- Discuss the instrumentation and application of DSC.
- Enlist the different X-ray Diffraction techniques and explain the application of X-ray
- diffraction.
- Explain the methodology involved in the qualification of UV-VIS Spectrophotometer.
- Describe the principle and procedure involved in the solid phase extraction.
- Discuss in detail cGmp guidelines according to CDER USFDA
- Discuss about design a qualification and describe the qualification GC.
- Explain the principle, advantages and requirements of Radio Immuno Assay.
- Define Chemical shift. Explain nuclear Over Hauser effect.
- Discuss the principle of NMR Spectroscopy.
- How are X-ray produced? What are modification of X-ray tube?
- Explain the principle and procedure involved in the liquid-liquid extraction.
- Explain the methodology involved in the qualification of GC.
- Describe the Radio Immunological assays and bioluminescence assay.
- Classify chromatographic methods and explain the instrumentation of HPLC
- What is theoretical plate, HETP, retention and asymmetry factor.
- Discuss the concept X-ray Crystallography.
- Briefly outline the instrumentation of Mass Spectrometer.
- State and derive the an equation for Braggs law.
- Explain the methodology involved in the qualification of HPLC.
- Explain the utilization of ELISA technology in the measurement of biological activities
- Write the various components, Limitations and application of Radio Immune Assay
- Explain validation parameter for electronic balance.
- Give a brief outline of principle of FT-NMR and CNMR
- Discuss in detail about the HPTLC technique.
- With a suitable diagram explain the construction and working of HPLC.
- Briefly outline the instrumentation of Mass Spectrometer.
- State and derive the an equation for Braggs law.
- Explain the methodology involved in the qualification of HPLC.
- Explain the utilization of ELISA technology in the measurement of biological activities
- Write the various components, Limitations and application of Radio Immune Assay
- Explain validation parameter for electronic balance.
- Enlist different ionizers used in MS and explain any one in detail.
- Discuss in detail about the HPTLC technique.
- Write the construction and working of HPLC.
- Explain the fragmentation pattern rules used in Mass spectroscopy.
- Explain the technique involved in thermal. Gravimetric analysis with suitable Examples
- Explain the different parts of Mass spectrometer with neat diagram.
- Explain the utilization of ELISA technology in the measurement of biological activities
- What are the factors to be considered during preparation of HPLC Analyses of drug
- products
- What is theoretical plate and explain any one detail.
- Discuss in detail the various detectors used in GC.
- Write note on bioluminescence assay, Enlist the application of ELISA.
- Explain the production and detection of X-rays by Debye Scherrer method.
- Explain the principle and instrumentation of NMR Spectroscopy.
- Write the principle of TGA. What factors are responsible for affecting TGA results
- Explain the terms of Chemical shift and Spin-Spin coupling, Coupling constant.
- Write the principle involved in the rotating crystal technique in X-ray diffraction
- spectroscopy.
- Explain the principle and different methods of Radio Immuno Assay.
- Explain the methodology involved in the qualification of HPLC.
- Describe the principle and procedure involved in the solid phase extraction.
- Explain the method involved in the qualification of
- Explain the various derivatization techniques in GC
Short answer 2 marks
- Enlist different ionizers used in MS.
- Define the Braggs law.
- Define and classify validation.
- Write the Limitations of Radio Immuno Assay.
- Differentiate between ELISA and RIA.
- Write applications of DTA.
- Important applications of IR.
- Write any one sampling technique of LC-MS.
- Name the ideal carrier gas used in Gas Chromatography
- What is HPTLC.?
- Solvent used in NMR Spectroscopy
- Applications of X Ray.
- Flame photometer
- ELISA.
- Define Radio Immuno Assay
- Spin-Spin coupling
- define Bragg’s law
- Important feature of qualification of UV-Visible.
- Classify different methods of Radio Immuno Assay
- HPTLC
- What is Shielding and De- shielding?
- What is single crystal diffraction.?
- Mention validation methods with examples
- Write the Limitations of Radio Immuno Assay.
- Application as the diagnostic test for HIV.
- Write its merits and demerits of HPLC.
- Write important applications of IR.
- Write sampling techniques of LC-MS.
- Qualification of UV Spectrophotometer.
- Detectors used in GC.
- Application of GC.
- Qualification of Fluorimeter.
- Define Singlet and Doublet.
- Applications of IR.
- Radio Immuno Assay
- Spin-Spin coupling
- What is plate theory and rate theory
- Important feature of qualification of UV-Visible.
- Define full validation and partial validation.
- Advantages of HPTLC.
- Classify different kinds of ELISA
- Define Singlet and Doublet.
- Define full validation and partial validation.
- Applications of IR.
- Radio Immune Assay.
- Qualification of IR Spectrophotometer.
- What is plate theory and rate theory
- Important feature of qualification of UV-Visible.
- Define Bragg’s law.
- Internal standard used in NMR.
- Factors influencing on Chemical Shift
- Write the concept of Miller indices
- Define Bragg’s law
- Name the detector used in Flame Photometer
- Qualification of IR Spectrophotometer
- Define ELISA and its uses
- Important feature of qualification of UV-Visible
- Application of GC
- Detection method methods in HPTLC
- Detectors used in HPLC
- Define quenching and give example
- Detector used in Flame Photometer.
- Define Singlet and Doublet.
- Enlist application of ELISA..
- Write the various components Radio Immune Assay
- Spin-Spin coupling
- What is plate theory and rate theory
- Enlist the ICH guidelines
- Define validation
- Advantages of HPTLC.
- Enumerate the application of HPTLC.
- Name the gases used in flame emission spectroscopy.
- Define Singlet and Doublet.
- Enlist the application of ELISA..
- Write the various components Radio Immune Assay
- Spin-Spin coupling
- What is plate theory and rate theory
- Define molecular ion and fragment ion
- Define validation
- Operational qualification
- Detectors used in GC.
- Define Coupling constant..
- What is Chemical Shift?
- Advantages of FT-IR Spectrophotometer
- Write the various components Radio Immune Assay
- Spin-Spin coupling
- What is rate theory?
- Installation qualification for UV
- Define validation
- Advantages of HPLC.
- What is Chemical shift? Write it significance
- Enlist the different X-ray Diffraction techniques.
- Define full validation & partial validation.
- Enumerate the different types of ELISA methods.
- Write importance of Radio Immuno Assay.
- Name the different derivatizations used in GC.
- Write the factors during preparation of HPLC Analyses drug products.
- Write sampling techniques of GC-MS.
- Define validation and explain different type of method validation
- 100.Detectors used in HPLC